Transport infant incubator HB-YP90AB
on casterswith phototherapy lampelectric

Transport infant incubator - HB-YP90AB - Rooe Medical - on casters / with phototherapy lamp / electric
Transport infant incubator - HB-YP90AB - Rooe Medical - on casters / with phototherapy lamp / electric
Add to favorites
Compare this product
 

Characteristics

Configuration
transport
Features
on casters
Options
with phototherapy lamp
Other characteristics
electric
Weight

63 kg, 68 kg
(138.9 lb, 149.9 lb)

Length

1,085 mm, 1,125 mm
(42.7 in, 44.3 in)

Width

640 mm, 665 mm
(25.2 in, 26.2 in)

Height

725 mm, 910 mm
(28.5 in, 35.8 in)

Description

Incubators and radiant warmers are used to maintain the body temperature of newborn infants. This is best done so that the energy expended for metabolic heat production is minimized. The heat output of these devices is usually regulated by servocontrol to keep the skin temperature constant at a site on the abdomen where a thermistor probe is attached. Product Description Hospital NICU Incubator Transport Infant Incubator Features: Two control modes: Air mode and baby mode controlled by micro-computer Set temperature, air temperature, baby temperature are displayed separately; Natural air flow humidity Inclination of bassinet is adjustable Failure alarm indication; RS-232 connector; Oxygen input interface; HB-90AB is configured nicu incubator,transport infant incubator,hospital incubator Equipment model: HBXHZ-90 (with blue fluorescence lamp) DC motor. ■Standard Configuration: HB-90AB: Based on HB-90A, with Neonate bilirubin phototherapy equipment model: HBXHZ-90 (fixed model). ■Optional Configuration: > 37°C temperature override mode function, Vertical height adjustment stand(VHA stand), Weighing system, SP02, Neonate bilirubin phototherapy equipment model: HBXHZ-90L (fixed model), Disposable skin temperature sensor. ■Specification: Power requirement: AC220V-230V/50Hz or AC110-120V/50-60Hz, 850VA Mode of control: Air mode and baby mode controlled by micro-computer Control range of air temperature: 25°C -37°C (override mode: 37-39°C is optional) Control range of baby temperature: 34-37°C (override mode: 37-38°C is optional) Accuracy of skin temperature sensor: ±0.2°C The temperature difference between incubator temperature and average incubator
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.