Medical gas manifold YDJHC-A series
supplyhigh-pressure

Medical gas manifold - YDJHC-A series - Weclearmed - supply / high-pressure
Medical gas manifold - YDJHC-A series - Weclearmed - supply / high-pressure
Medical gas manifold - YDJHC-A series - Weclearmed - supply / high-pressure - image - 2
Medical gas manifold - YDJHC-A series - Weclearmed - supply / high-pressure - image - 3
Medical gas manifold - YDJHC-A series - Weclearmed - supply / high-pressure - image - 4
Medical gas manifold - YDJHC-A series - Weclearmed - supply / high-pressure - image - 5
Add to favorites
Compare this product
 

Characteristics

Applications
for medical gas
Options
supply, high-pressure

Description

Weclearmed® ambulance oxygen manifold is suitable for ambulances with large oxygen consumption, where bottled high-pressure oxygen is fed into the main pipe of the control panel through a metal hose. After depressurized, the high pressure oxygen is transported to the oxygen terminal through the low pressure pipeline, which is used as a source of oxygen for first aid. The working principle is to decompress the high pressure oxygen into low pressure, which is delivered to the oxygen terminal through the respective pipeline. Product Description Weclearmed® ambulance oxygen manifold has a control panel which can connect two or more oxygen cylinders at the same time. To decompress the high pressure oxygen to a low pressure. Ambulance manifold system is a kind of equipment of centralized gas supply system.The control panel consists of metal hoses which are connected to the oxygen cylinders through G5/8 threads, and each cylinder is connected to the control panel with a corresponding high-pressure switching valve, which controls the respective high-pressure pipeline separately.The high-pressure piping connecting each oxygen cylinder at the end of the switching valve connected each other. The tee joint at the centre of gas manifold to link the high-pressure gauge, regulator and high-pressure pipeline.The high pressure gauge is used to monitor the oxygen pressure in the control panel's high pressure tubing.The regulator is used to regulate the high pressure oxygen to the required pressure and then output to the low pressure end.The low-pressure end is connected to the oxygen terminal, safety valve and low-pressure gauge.

Catalogs

No catalogs are available for this product.

See all of Weclearmed‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

ArabHealth 2025
ArabHealth 2025

27-30 Jan 2025 Dubai (United Arab Emirates) Hall Z7 - Stand D19

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.