DEXA bone densitometer D2
cone beamfor forearm bone examination

DEXA bone densitometer - D2 - Xuzhou Pinyuan Electronic Technology - cone beam / for forearm bone examination
DEXA bone densitometer - D2 - Xuzhou Pinyuan Electronic Technology - cone beam / for forearm bone examination
DEXA bone densitometer - D2 - Xuzhou Pinyuan Electronic Technology - cone beam / for forearm bone examination - image - 2
DEXA bone densitometer - D2 - Xuzhou Pinyuan Electronic Technology - cone beam / for forearm bone examination - image - 3
DEXA bone densitometer - D2 - Xuzhou Pinyuan Electronic Technology - cone beam / for forearm bone examination - image - 4
Add to favorites
Compare this product
 

Characteristics

Bone densitometer type
DEXA
Beam shape
cone beam
Type of imagery
for forearm bone examination

Description

X-ray bone density and skeletal age instrument D2,Dual measurement system for bone density andskeletal age. Product introduction: The X-ray bone density and skeletal age instrument is a product that integrates the X-ray bone density measurementand bone age measurement. The X-ray skeletal age instrument uses X-rays to photograph the hand bones, and displaysthe hand bone photography images using the skeletal age analysis system software. Based on the mature characteristicsof the finger and wrist bones, the software determines the bone age of the subject, and completes the evaluation of boneage. The dual-function X-rav bone density and skeletal age instrument uses the X-ray absorption detection method toobtain high-energy and low-energy image data based on the different absorption levels of X-rays by bones and tissues otdiferent densities. The energy subtraction method is used to eliminate the influence of soft tissue on bone density measurement, The image is then analvzed and processed by software to obtain bone density measurement data while eliminat. ing the influence of soft tissue to measure bone density value of the measured site. Scope of application: Suitable for measuring bone density values in the distal radius and uina of patients. Suitable forminors aged 4-15 in need of skeletal development assessment. Bone age detection sites : phalanges, metacarpals, and wrist bones Scanning method : cone beam scanning Bone age assessment algorithm : TW3-RUS, TW3-C RUSRUS-CHN, TW3-C Carpal, CHN Loading time : ≤ 0.32s Adopting fully enclosed lead protection method : Either simplifed or detailed reports