video corpo
  • Products
  • Catalogs
  • News & Trends
  • Exhibitions

Compact multi-parameter monitor M7
portableECGRESP

Compact multi-parameter monitor - M7 - Yonker - portable / ECG / RESP
Compact multi-parameter monitor - M7 - Yonker - portable / ECG / RESP
Compact multi-parameter monitor - M7 - Yonker - portable / ECG / RESP - image - 2
Compact multi-parameter monitor - M7 - Yonker - portable / ECG / RESP - image - 3
Compact multi-parameter monitor - M7 - Yonker - portable / ECG / RESP - image - 4
Compact multi-parameter monitor - M7 - Yonker - portable / ECG / RESP - image - 5
Add to favorites
Compare this product
 

Characteristics

Configuration
compact, portable
Measured parameter
ECG, RESP, TEMP, pulse rate, NIBP, IBP, SpO2
Applications
intensive care, transport
Technology
pulse wave analysis
Screen size

7 in

Battery life

2 h

Weight

1.4 kg
(3.1 lb)

Pulse rate

Min.: 40 unit

Max.: 240 unit

Oxygen level

Min.: 0 %

Max.: 100 %

Description

Quality Standards and Classification CE, ISO13485 SFDA: Class Ⅱb Anti-electroshock degree: ClassⅠequipment (internal power supply) TEMP/SpO 2 /NIBP: BF ECG/Resp: CF Environment Operating environment : Temperature: 0 ~ 40 ℃ Humidity: ≦ 85 % Pressure: 86.0 kPa ~ 106.0kPa Transport and Storage environment : Temperature: -20 ~ 55 ℃ Humidity: ≦ 93 % Pressure: 86.0 kPa ~ 106.0kPa Power Requirements AC: 100 ~ 240V, 50Hz/60Hz DC: Built-in rechargeable battery Battery: 11.1V 24wh Li-ion battery 5min operating after low battery alarm Date Storage Trend diagram/table: 720h NIBP review: 10000 events Wave review: 12h Alarm review: 200 alarm events Support drug concentration titration analysis ECG 5 Leads: RA, LA, LL, RL, V Lead mode: Ⅰ,Ⅱ, Ⅲ, AVR, AVL, AVF, V Gain: × 1.25mm/mV,2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV (error ≤ 5%) Sweep speed: 6.25mm/s,12.5mm/s,25mm/s, 50mm/s (error ≤ ± 10%) Bandwidth: Surgery 1 ~ 25 Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 130 Hz Sensitivity: >200 μ V P-P CMRR: ≥ 112dB Differential Input Impedance: >5M ohm Electrode Offset Potential: ±300mV Polarization Voltage: ≥ ± 500mV Input Impedance: ≥ 5 M Caliration Voltage: 1mV ± 5% SpO2 Resolution: 1% Accuracy: 70% ~ 100% ± 2% 40% ~ 69% ± 3% Pulse Rate Resolution: 1bpm Accuracy: ± 3bpm RESP Method: impedance between RA-LL Resp Impedance range: 0.3 ~ 3 Ω Base Impedance range: 200 Ω ~ 4000 Ω Bandwidth: 0.3 ~ 2.5Hz Gain: × 0.25, × 0.5, × 1, × 2, × 4 Resp rate: Measurement Range Adult 0 ~ 120BrPM Neonatal/Pediatric 0 ~ 150BrPM Resolution: 1BrPM Accuracy: 7 ~ 150BrPM ( ± 2BrPM) 0 ~ 6BrPM (unspecified) Apnea Alarm: 10 ~ 40s
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.