video corpo

Analog mammography unit YSX980D
full-field digitalfor stereotactic breast biopsies

Analog mammography unit - YSX980D - YSENMED - full-field digital / for stereotactic breast biopsies
Analog mammography unit - YSX980D - YSENMED - full-field digital / for stereotactic breast biopsies
Add to favorites
Compare this product
 

Characteristics

Mammography type
analog, full-field digital
Application
for stereotactic breast biopsies

Description

High frequency mammography x-ray machine YSX980D X-ray Generator Generator Type: High Frequency Inverter 40kHz Input Power: Single phase 220VAC, 50/60Hz Radiographic Ratings: Large Focal Point 20-35KV/1-300mAs Small Focal Point 20-35KV/1-100mAs Power Rating:1.2kW X-ray Tube Model: Fixed anode, China Hang Zhou XD7(X791) Focal Spot Size: Dual Focus 0.5mm Target Material: Molybdenum (Mo) Port Material: Beryllium (Be) Anode Heat Storage: 63KHU Anode Cooling: Air cooling Filtration: Mo(0.03mm),Al(0.5mm) Radiographic Stand C-ARM: Vertical Movement:60cm (70~130cm) Motorized Rotations Deg:±180° Motorized (Deg. Data Display) SID: 65cm Cassette Image Receptor 18×24cm Line Voltage 220Vac@15A, Single phase Comfortable Compression(Optional) When some degree of pressure is required for radiography, it allows you to presser the appropriate pressure(up to a maximum of 20kg)and is equipped with MICOM Control's Soft-touch system which is designed to minimize the discomfort of the examine with in the pressure range. Tissue Compression: Manual and Motorized (Max 20kg) Compression Force and Thickness Data Display Micom Control's Compression Automatic Release Intelligent Automatic Exposure Control (AEC) (Optional) With the Automatic Exposure Control system, it is possible to produce images with reliable intensity suitable for and film, screen, or method of radiography. Furthermore, it greatly enhances the convenience of radiography by embedding the Full-AEC function which is capable of utilizing the Auto kV Type: Solid-State Detector or PMT Detector Microprocessor Control AEC Mode: Full AEC(Auto kV) Semi AEC (KV Select) Manual (kV, mAs Select) Density Adjustment: 10 density steps

Catalogs

No catalogs are available for this product.

See all of YSENMED‘s catalogs

Other YSENMED products

Radiology

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.