Neonatal intensive care CPAP machine YSAV-5A-M
sleep apnea therapyauto CPAPinfant

Neonatal intensive care CPAP machine - YSAV-5A-M - YSENMED - sleep apnea therapy / auto CPAP / infant
Neonatal intensive care CPAP machine - YSAV-5A-M - YSENMED - sleep apnea therapy / auto CPAP / infant
Neonatal intensive care CPAP machine - YSAV-5A-M - YSENMED - sleep apnea therapy / auto CPAP / infant - image - 2
Neonatal intensive care CPAP machine - YSAV-5A-M - YSENMED - sleep apnea therapy / auto CPAP / infant - image - 3
Add to favorites
Compare this product
 

Characteristics

Application domain
neonatal intensive care
Applications
sleep apnea therapy
Ventilation mode
auto CPAP
Patient type
infant, premature

Description

Introduction Bubble CPAP is a special medical equipment for supporting of babies’ breath which devised and manufactured based on the wide application of closed continuous NCPAP in department of pediatrics. It applies in the course of ventilation treatment of Nasal-CPAP for premature, neonate, infant to children below 14 year old. The mode of CPAP can reduce babies’ WOB effectively, while keeping the autonomous respiration well. Features Supply a safe and controllable FIO2; Keep the FRC effectively; Reduce infant’s WOB; Reduce the need of invasive mechanical ventilation; Supply better warm and humid gas; Reduce the occurrence rate of the CLD; Improve the physical sighs, such as height, weight. Parameter: Mixed gas source An air oxygen blender and a medical air compressor are integrated in the main machine which supplies an adjustable oxygen concentration from 21% to 100% and flow rate up to 10 L/min Respiratory humidifier It is used to warm and add humidity to mixed gases at constant level. The humidified blended oxygen is then circulated through corrugated tubing Bubble generator Reusable and unbreakable, adjusting the CPAP from 3 to 10 cmH2O Patient interface Nasal prongs of various sizes are adopted as patient interface to connect breathing circuit with patient' s airway FIO2: 21%~100% Flow: 0~18LPM CPAP pressure: 0.3~1.0kPa(3~10cmH2O) Pressure lack alarm: When the oxygen-source suspended or interrupted, sound alarm. Noise: <55dB(A)

VIDEO

Exhibitions

Meet this supplier at the following exhibition(s):

Medica West Africa 2025
Medica West Africa 2025

2-04 Jun 2025 Landmark Center, Lagos (Nigeria)

  • More information
    PhiMedical Expo 2025
    PhiMedical Expo 2025

    13-15 Aug 2025 SMX Convention Center, Manila (Philippines)

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.