video corpo

Femoral intramedullary nail
tibiaproximal fixationdistal fixation

Femoral intramedullary nail - Zimmer Biomet - tibia / proximal fixation / distal fixation
Femoral intramedullary nail - Zimmer Biomet - tibia / proximal fixation / distal fixation
Femoral intramedullary nail - Zimmer Biomet - tibia / proximal fixation / distal fixation - image - 2
Femoral intramedullary nail - Zimmer Biomet - tibia / proximal fixation / distal fixation - image - 3
Femoral intramedullary nail - Zimmer Biomet - tibia / proximal fixation / distal fixation - image - 4
Femoral intramedullary nail - Zimmer Biomet - tibia / proximal fixation / distal fixation - image - 5
Femoral intramedullary nail - Zimmer Biomet - tibia / proximal fixation / distal fixation - image - 6
Femoral intramedullary nail - Zimmer Biomet - tibia / proximal fixation / distal fixation - image - 7
Add to favorites
Compare this product
 

Characteristics

Joint / bone
femur, tibia
Fixation
proximal fixation, distal fixation
Side
right, left
Materials
metallic
Length

Min.: 24 mm
(0.9 in)

Max.: 48 mm
(1.9 in)

Proximal diameter

15.5 mm
(0.6 in)

Degree of curvature

4 °, 15 °

Description

The ZNN System is the first Zimmer Biomet product to have the Bactiguard coating, offering the combination of a unique non-antibiotic-eluting, anti-infective coating with a clinically successful intramedullary nailing system. This pairing is designed to provide a promising solution for addressing implant-associated infection and improving patient satisfaction and outcomes. Infection Control Infection control is a top priority for trauma surgeons. Below you can find key statistics and a poignant patient video testimonial, which highlights the reason we need to talk more about infection control and prevention. Bactiguard Technology Bactiguard Technology is a thin, durable4 and non-eluting noble metal (gold, silver and palladium alloy) coating that is designed to firmly attach to the implant surface. When the coating comes into contact with moisture, the noble metals create a unique galvanic (or battery) effect that generates tiny pico currents on the implant surface, designed to reduce bacterial adhesion and subsequent risk of biofilm formation.

VIDEO

Catalogs

No catalogs are available for this product.

See all of Zimmer Biomet‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.