F-DGSi gas generators
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Output: 15, 35, 70, 64, 25 l/min
Output pressure: 8 bar
Gas purity: 99.99 %
... an option guarantees continuous gas supply, independent of in house compressed air supply. SIMPLE INSTALLATION Gas generators can be installed in the laboratory, on or under a bench, ...
F-DGSi
Output: 1, 2, 3 l/min
Output pressure: 6 bar
Gas purity: 99.9995 %
... an option guarantees continuous gas supply, independent of in house compressed air supply. SIMPLE INSTALLATION Gas generators can be installed in the laboratory, on or under a bench, ...
F-DGSi
Output: 0.11 l/min - 1.5 l/min
Output pressure: 1 bar - 11 bar
Gas purity: 100 %
The COSMOS MF.H2 Generator is designed for GC-carrier gas and detectors requiring Hydrogen fuel gas, such as FID, FPD, NPD and TCD. The Hydrogen gas is produced from ...
F-DGSi
Output: 0.11 l/min - 0.6 l/min
Output pressure: 1 bar - 7 bar
Gas purity: 99.9996 %
... allows safe use of the gas generators where the use of cylinders is risky or prohibited. The application of tested safety technologies stops the unit in the event of leaks or malfunctions SIMPLE ...
F-DGSi
Output: 0.11 l/min - 0.6 l/min
Output pressure: 1 bar - 11 bar
Gas purity: 99.9996 %
... allows safe use of the gas generators where the use of cylinders is risky or prohibited. The application of tested safety technologies stops the unit in the event of leaks or malfunctions SIMPLE ...
F-DGSi
Output: 0.1 l/min - 1.35 l/min
Output pressure: 0.1 bar - 11 bar
Gas purity: 99.999 %
... allows safe use of the gas generators where the use of cylinders is risky or prohibited. The application of tested safety technologies stops the unit in the event of leaks or malfunctions SIMPLE ...
F-DGSi
Output: 0.1 l/min - 0.6 l/min
Output pressure: 0.1 bar - 11 bar
Gas purity: 99.9996 %
... allows safe use of the gas generators where the use of cylinders is risky or prohibited. The application of tested safety technologies stops the unit in the event of leaks or malfunctions SIMPLE ...
F-DGSi
Output: 70, 35 l/min
Output pressure: 7 bar
Gas purity: 99.999, 99 %
... an option guarantees continuous gas supply, independent of in house compressed air supply. SIMPLE INSTALLATION Gas generators can be installed in the laboratory, on or under a bench, ...
F-DGSi
Output: 70, 35 l/min
Output pressure: 6, 7 bar
Gas purity: 99.999, 99 %
... an option guarantees continuous gas supply, independent of in house compressed air supply. SIMPLE INSTALLATION Gas generators can be installed in the laboratory, on or under a bench, ...
F-DGSi
Output: 70, 35 l/min
Output pressure: 7 bar
Gas purity: 99.999, 99 %
... an option guarantees continuous gas supply, independent of in house compressed air supply. SIMPLE INSTALLATION Gas generators can be installed in the laboratory, on or under a bench, ...
F-DGSi
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining