Memmert dry heat sterilizers

33 companies | 102 products
laboratory autoclave
laboratory autoclave
Steroclave 55

Capacity: 55 l
Temperature range: 101 °C - 138 °C
Sterilization cycle time: 1 min - 99 min

... steel AISI304, the working vessel and lid is in stainless steel AISI 316 internally mechanically polished (mirror finishing). Hot air and exhausted steam are condensed and collected in a proper tank, ...

dental sterilizer
dental sterilizer
749/00

Capacity: 30 l
Temperature range: 0 °C - 230 °C

DRY STERILIZER 30 LITERS, complete with 4 shelves,Temperature from 0°C to 200°C. Stainless steel made,with painted door,to have the maximum resistence,to heat and time. The 4 shelves ...

See the other products
Carlo De Giorgi
medical sterilizer
medical sterilizer
LX400HAS

Capacity: 25 l
Temperature range: 0 °C - 100 °C
Width: 470 mm

Benchtop Hot Air Sterilizer LX400HAS is a benchtop design, back heating, horizontal force convection with adjustable air speed to ensure chamber temperature uniformity. This is utilized ...

medical sterilizer
medical sterilizer
DOF-HAS-A series

Capacity: 138, 188, 70, 57, 34 l
Temperature range: 10 °C - 250 °C
Width: 630, 830, 540, 845, 890 mm

Dry heat sterilizer DOF-HAS-A Series uses high-temperature dry heat to oxidize microorganisms, denature proteins, and cause poisoning due to electrolyte ...

medical sterilizer
medical sterilizer
35581

Capacity: 60 l
Temperature range: 0 °C - 200 °C
Sterilization cycle time: 0 min - 120 min

• STANDARD UNIT • Inside dimensions (mm): 535x320xh 345 Inner structure and height adjustable inner shelves completely made of stainless steel. Door with lock and key. Standard unit: Double resistance for reaching high temperatures ...

medical sterilizer
medical sterilizer
35586

Capacity: 20 l
Temperature range: 0 °C - 200 °C
Sterilization cycle time: 0 min - 250 min

... bottom of the right side and on the top of the left side for hot air adjustment and circulation, which is useful for a quick cooling of the device. - electronic running C.P.S. - optimum heat ...

clean room sterilizer
clean room sterilizer
SteriEvent

Capacity: 1,500, 3,125, 420, 560 l
Temperature range: 250, 300, 350 °C
Width: 2,150, 1,650, 1,900 mm

... safely and cost-effectively sterilise samples or products, then the process of dry heat serialisation is an interesting alternative to the other existing procedures. Only hot air ...

medical sterilizer
medical sterilizer
50287

Temperature range: 250 °C
Sterilization cycle time: 2 min - 5 min
Width: 5 in

... well without discomfort. Sterilization of the inserted parts by dry heat (250° C) takes 2-5 seconds. The working end is sterile before the handles get hot. Small Footprint The sterilizer’s ...

medical sterilizer
medical sterilizer
H Series

Capacity: 30 l - 2,400 l
Temperature range: 7 °C - 200 °C
Width: 369 mm - 2,214 mm

Steridium’s new generation of hot air sterilizers have been designed to the highest European standards and manufactured to ensure performance, reliability and repeatability demanded medical ...

exhibit your products

& reach your clients in one place, all year round

Exhibit with us