Stryker femoral stems

Femoral stem offset: 7, 6 mm
CCD angle: 132 °
... Distal tip The tapered design and the glossy finishing avoid load concentration on the femoral cortex thus postoperative thigh pain. MATERIALS The EXACTA RS stems for cementless press-fit application ...

Femoral stem length: 137, 177 mm
Femoral stem offset: 37.4, 46.9 mm
CCD angle: 132 °
... Proximally tapered stem geometry converts the shear forces to compressive load. • This helps the stem to resist subsidence and medial migration. Extensive Stress Distribution • Low elastic modulus ...
Corentec

CCD angle: 125, 135 °
The EUROSTEM implant is a quadrangular femoral stem with trapezoidal proximal section and a conical distal section inspired by the CORAIL® philosophy and dedicated to hip arthroplasty. The EUROSTEM range ...
EUROS

CCD angle: 135 °
... wear resistance: cementes stem is made of REX steel, cementless is of titanium. Cementless mircoporotic surface can be titanium plasma or Hydroxi-apatite as well. With the wide range of stems, resps functioning ...
Sanatmetal

... old fracture of the femoral neck, pain from destruction of the femoral head or acetabulum, resulting in impairment of joint function; 2. Patients with avascular necrosis of the femoral ...
Wuhan Yijiabao Biological Materials

Femoral stem length: 130, 155 mm
Dia. Ø 9 to 15 mm Available in stainless Steel Available Length are 130 to 155 mm (5 mm Variation)

CCD angle: 135, 125 °
The progressive trapezoidal geometry enables optimal adaptation of the stem and both anti-translational and anti-rotational fixation that provides perfect primary stability while preventing the hip prosthesis from sinking. Specifications Standard ...
Surgival

... stabiliztion. · High-polished surface helps to reduce friction. · Distal centralizer prevents stem tilting in the cavity. Indicatons: · Femoral neck fracture · Femoral head osteonecrosis · ...
Irene Ortho

CCD angle: 130 °
P130® cemented femoral stem for the replacement of the natural hip joint during first intention. Range of products: The metaphyseal profile of the stem ensures the implant’s primary ...
C2F Implants

Ortosintese

Femoral stem length: 1, 10 mm
Femoral head diameter: 22.2 mm - 36 mm
CCD angle: 120, 130 °
... , neutral femoral stems. DESIGN DESIGN FRENCH MANUFACTURE Proximal metaphyseal anchorage ensures primary stability The 80µm hydroxyapatite surface effect ensures secondary anchorage One instrumentation, ...

1. Based on the classic theory of EXETER polishing design; 2. Highly polished surface minimizes the wear between the prosthesis and cement; 3. Double cone collar-free design: Allows the prosthesis to sink slightly in the cement sheath ...

... the hydroxyapatite coating, ensures stability in the long term. 3 options are offered: - Standard Filler stem - TI Filler stem - Collar Filler stem From 8 to 20 Features Conus: 5°42'30'' ...
Biotechni

... cracking Tapered stem shape and implant collar provide stability against subsidence Uniform cement mantle is present over the entire length of the implant Flat hexagonal stem profile provides a high ...
Peter Brehm

Femoral stem length: 130 mm
CCD angle: 140 °
Material: Stem - Wrought high nitrogen stainless steel (ISO 5832-9) Centralizer - PMMA
Beznoska

CCD angle: 120 °
... Hype® range of femoral stem is a complete range of self locking stems dedicated to primary total hip arthroplasty. CHARACTERISTICS AND MATERIALS Characteristics : Homothetic size ...
SERF

Femoral stem length: 160, 95 mm
The Entrada Hip Stem integrates a wealth of clinical history—hydroxyapatite coating, compaction broaching, taper wedge geometry—and provides critical refinements—progressive neck lengths, consistent proximal body growth, ...
Ortho Development

Femoral stem length: 200, 250 mm
CCD angle: 140 °
Based on the proven design of the Furlong® H-A.C. stem the clinically proven stem geometry provides exceptional primary mechanical stability with market-leading long term clinical success. Key Features Simple ...
JRI Orthopaedics

CCD angle: 135 °
CINEOS® prostheses consist of femoral stems designed for the replacement of the natural hip joint during first intention or during revision surgery. 10 sizes 12/14 taper Without collar Forged Titanium ...
X-NOV Medical Technology

Femoral stem length: 6.25, 20 mm
The concept of this femoral component relies on a dose prosthesis-bone contact in both medial and lateral zones. The stem geometry shows a proximal to distal 3 degree taper providing a greater femoral ...
Biotech Medical

Femoral head diameter: 22.2 mm - 36 mm
CCD angle: 130, 122 °
... to choose between a standard stem (130° neck-shaft angle) and a lateralised stem (122° neck-shaft angle) during the preoperative planning phase or during the procedure itself. Features and materials ...
FH Orthopedics

Femoral stem length: 305, 265, 225, 190 mm
Femoral stem offset: 41.5 mm
Femoral head diameter: 14 mm - 25 mm
Indicated for partial or total uncemented revision hip arthroplasty. The Vegamaxx nail follows a cylindrical and wedge-shaped profile, its fixation is carried out in the distal portion of the femur. – Anatomical design, with smooth ...
BAUMER

... stability of the prosthesis, anti-rotation; 3. Microporous titanium coating: Provide good pore space for bone ingrowth; 4. Short stem design: Maximize bone remain and leave bone for revision; 5. Curved distal end patented ...
Beijing Chunli Technology Development

Femoral stem length: 320 mm
CCD angle: 128, 135 °
... load axis choice of 4 surface finish (with and without cement) choice of 2 stem lengths in primary cementless stems: normal or -15mm (on average) revision cementless stems available ...
EVOLUTIS

With a stem made out of drop forged cobalt chrome and a small cement color, this device is constructed to help patients with leg injuries and pain. Some of its indications include rheumatoid arthritis, fractures, tumors, ...
Your suggestions for improvement:
Subscribe to our newsletter
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining